Question 14 of 18
That answer is incorrect.
The correct protocol to follow when completing work on a patient after utilizing nitrous oxide is to:
turn off the nitrous oxide
increase the oxygen to maintain the tidal
volume (for example, increase it to 6 liters)
allow the patient to breathe 100% oxygen for
the following specified times: for every 15 minutes on nitrous oxide,
the patient is to receive 5 minutes of 100% oxygen - In this
instance, your patient had nitrous oxide-oxide analgesia 30 minutes,
therefore he would need 100% oxygen for 10 minutes.